If you leave the key in the ignition switch, someone could accidently start the engine and seriously injure you or bystanders.
Remove the key from the ignition switch before you do any maintenance.
Park the machine on a level surface.
Engage the parking brake.
Lower the cutting units.
Shut off the engine and remove the key.
Open the hood (Figure 1).

Rotate the battery disconnect switch to the OFF position, refer to the Operator’s Manual for your machine.
Parts needed for this procedure:
| Solenoid | 1 |
| Bolt (1/4 x 3/4 inch) | 2 |
| Flange locknut | 2 |
| Fuse-holder | 1 |
| Jumper strap | 1 |
| Fuse (100 A) | 1 |
| Flange nut (8 mm) | 2 |
| Flange nut (5/16 inch) | 2 |
| Red insulator | 1 |

Align the holes in the solenoid with the holes in the electrical bracket (Figure 4).

Secure the solenoid to the bracket (Figure 4) with the 2 bolts (1/4 x 3/4 inch) and 2 flange locknuts (1/4 inch).
Insert the L-tab (right) of the fuse-holder into the right slot in the electrical bracket (Figure 5).

Insert the locking clip (left) of the fuse-holder into the left slot in the electrical bracket until the fuse holder snaps securely into the bracket (Figure 5).
Install the pink-wire connector labeled COIL + [CAB CONTACTOR] to the left post at the bottom of the solenoid (Figure 6).

Install the black-wire connector labeled COIL - [CAB CONTACTOR] to the right post at the bottom of the solenoid (Figure 6).
Assemble the ring terminal with the 2 red wires of the machine wire harness onto the left post of the solenoid and secure the terminal to the post (Figure 6) with a nut (5/16 inch).
Assemble the red insulator onto the jumper strap (Figure 7).

Assemble the jumper strap and insulator onto the right post of the fuse-holder and right post of the solenoid (Figure 8).

Loosely secure the strap to the right post of the solenoid (Figure 8) with a nut (5/16 inch).
Assemble the fuse (100 A) onto the left and right posts of the fuse-holder (Figure 9).

Assemble the ring terminal for the yellow wire of the machine wire harness onto the left post of the fuse-holder (Figure 9).
Assemble the 2 flange nuts (8 mm) onto the left and tight posts of the fuse-holder and tighten the nuts by hand (Figure 9).
Tighten the nut (5/16 inch) that secure the strap to the right post of the solenoid by hand
Close the cover of the fuse-holder until the cover snaps closed securely (Figure 10).

Rotate the battery disconnect switch to the ON position; refer to the Operator’s Manual for your machine.
Align the holes in side panel with the holes in the panel support of the machine; refer to Figure 2 in Removing the Side Panel.
Secure the side panel to the machine with the 2 knobs that you removed in Removing the Side Panel.
Close the hood and secure it.