Note: This kit is for Stage 5 machines only.

Safety

Safety and Instructional Decals

Graphic

Safety decals and instructions are easily visible to the operator and are located near any area of potential danger. Replace any decal that is damaged or missing.

decal140-2710

Installation

Preparing the Machine

  1. Park the machine on a level surface.

  2. Engage the parking brake.

  3. Lower the cutting unit(s).

  4. Shut off the machine and remove the key.

Installing the Kit

Parts needed for this procedure:

Slope sensor1
Carriage bolt (1/4 x 2 inches)2
Lock nut (1/4 inch)2
Spacer2
Slope sensor decal1
  1. Raise the platform. Refer to the traction unit Operator’s Manual.

  2. Remove the plastic bulkhead behind the seat.

  3. Install the slope sensor to the machine frame with 2 carriage bolts (1/4 x 2 inches), 2 spacers, and 2 flange nuts (1/4inch) to secure the slope sensor to the machine frame (Figure 1).

    g338090
  4. Locate the slope sensor connector in the main wire harness and plug it into the slope sensor.

  5. Use cable ties to secure the wire harness away from moving parts or pinch points.

  6. Install the slope-sensor decal adjacent to the machine-stability decal on the storage-pod lid (Figure 2).

    g308336

Installing the Fuse

Parts needed for this procedure:

Fuse (2 A)1
  1. Open the lid on the left pod.

  2. Remove the 3 knobs inside the storage pod (Figure 3).

    g338478
  3. Remove the storage pod and locate the fuse block.

  4. Remove the fuse-block cover and install the fuse in the location shown in Figure 4.

    g338477
  5. Install the fuse-block cover and install the storage pod with the 3 knobs.

Calibrating the Sensor

Note: When you first turn the ignition key to on, the InfoCenter shows advisory B2710, Calibrate Slope Sensor.

  1. While on a flat surface, remove the plug from the calibration connectors (Figure 5).

  2. Plug the calibration connectors together as shown in Figure 5.

    g350905
  3. Turn the ignition key to the ON position, but do not start the engine.

  4. The InfoCenter shows Message 600, Slope Sensor Calibrating.

    Note: The LED light at the top of the display screen blinks as the sensor calibrates.

    g317524
  5. When the InfoCenter shows Message 601, Slope Sensor Calibrated, Cycle keyswitch, and the light no longer blinks, turn the ignition key to the OFF position.

  6. Disconnect the calibration connectors and install the plug onto the connectors.

    g315597
  7. Install the plastic cover.

  8. Lower the seat platform and ensure it is latched.

Operation

Using the Slope Sensor

The light and alarm indicates the severity of the slope:

  • Red light—normal operating conditions

  • Slow, flashing red light and Advisory B2713 displaying on the screen—moderate slope

    g317557
  • Fast, flashing red light, audible alarm, and Advisory B2714 displaying on the screen—steep slope; proceed to a more shallow slope.

    g317558

Warning

Slopes are a major factor related to loss-of-control and tip-over accidents, which can result in severe injury or death.