Seat Belt Alarm Kit
Groundsmaster® 4500, 4700, or Reelmaster® 7000 Series Traction
Unit with ROPS
Installation Instructions
Note: This kit is compatible with traction unit models 30885, 30895, 30887,
30899, 03780, and 03781.
Safety
Safety
and Instructional Decals
 |
Safety decals and instructions
are easily visible to the operator and are located near any area of
potential danger. Replace any
decal that is damaged or missing.
|
Installation
Preparing
the Machine
 |
Caution |
|
If you leave the key in the ignition
switch, someone could accidently start the engine and seriously injure
you or bystanders.
Remove the key from the ignition
switch before you do any maintenance.
-
Park the
machine on a level surface, disengage the PTO, lower the cutting units,
and engage the parking brake.
-
Shut off
the engine, remove the key, wait for all moving parts to stop, and
allow the engine to cool.
Tilting
the Seat
-
Move the
seat latch
outward and carefully rotate
the seat up.
-
Ensure that
the forward prop rod
seats in the slot
detent of the rod-guide plate
.
Installing
the Inertial Measurement Unit (IMU)
Parts Required
| 1
|
IMU
|
| 2
|
Bolt (1/4 x 1 inch) |
-
Install the
IMU onto the oil filter bracket with 2 bolts (1/4 x 1 inch).
G608142
-
Bolt (1/4 x 1 inch)
-
IMU
-
Close and
latch the seat base.
Replacing
the Seat Belt Buckle
-
Remove the
existing seat belt buckle from the seat base by removing the bolt.
-
Install the
new seat belt buckle using the previously removed bolt.
-
Torque the
bolt to 55 N∙m (41 ft-lb).
Installing
the Alarm
Parts Required
| 1
|
Alarm
|
| 1
|
R-clamp
|
| 1
|
Bolt (5/16 x 3/4 inch) |
| 1
|
Alarm decal
|
-
Remove the
access panel from the control arm.
-
Install the
alarm decal on the top of the alarm in the orientation shown.
-
Secure the
alarm to the machine using the R-clamp, U-nut, and bolt (5/16 x 3/4
inch).
G608380
-
U-nut
-
R-clamp installed on alarm
-
Bolt (5/16 x 3/4 inch)
Installing
the Proximity Sensor
Parts Required
| 1
|
Proximity sensor
|
| 1
|
Proximity sensor bracket |
| 1
|
Nut
|
-
Remove and
discard the existing nut from the spacer bolt on the right side of
the ROPS.
-
Install the
proximity sensor bracket onto the ROPS using the nut provided.
-
Remove a
hex nut and lock washer from the end of the proximity sensor.
-
Install the
proximity sensor onto the bracket as shown and secure it with the
lock washer and hex nut.
G608509
-
Hex nut
-
Lock washer
-
Proximity sensor bracket
-
Proximity sensor
-
Nut
-
Adjust the
sensor so that it is 5 mm or less from the ROPS pin.
Routing
the Wire Harnesses
Parts Required
| 1
|
Seat belt alarm wire harness |
| 1
|
Proximity sensor wire harness |
| 2
|
Large cable tie
|
| 6
|
Small cable tie
|
-
Tilt the
seat open and support it with the prop rods.
-
Connect the
12-pin connector on the seat belt alarm wire harness to the IMU.
-
Install the
6-pin connector on the seat belt alarm harness into the expansion
port on the main wire harness.
-
Route the
seat belt alarm harness toward the back of the seat as shown.
-
Plug the
3-pin connector on the seat belt alarm harness into the proximity
sensor harness.
-
Route the
seat belt alarm harness to the outside of the seat as shown. Route
the proximity sensor harness behind the seat
as shown.
G608488
-
6-pin connector on seat belt alarm
harness; plug into expansion port on main wire harness
-
3-pin connector on seat belt alarm
harness; plug into the connector on the proximity sensor harness
-
Remaining portion of the seat
belt alarm harness; route to the outside of the seat
-
Remaining portion of the proximity
sensor harness; route behind the seat
-
12-pin connector on seat belt
alarm harness; plug into the IMU
-
Close and
latch the seat base.
-
Route the
proximity sensor harness along the telematics harness, up the roll
bar.
-
Connect the
2-pin connector on the proximity sensor harness to the proximity sensor.
-
Secure the
proximity sensor harness to the ROPS using cable ties as shown.
G608893
-
2-pin connector on proximity sensor
harness; connect to proximity sensor
-
Large cable tie
-
Small cable tie; connect to existing
magnetic mount
-
Route the
seat belt connector to the buckle, by running it under the buckle
spacer, and between the console and the buckle.
Ensure that
the seat belt buckle wire is routed on the outside of the seat belt
buckle to avoid pinched wires.
-
Remove 3
bolts on the armrest side panel to loosen the panel and allow space
to route the connectors.
-
Plug the
seat belt connector into the seat belt buckle. Plug the alarm connector
into the alarm.
G608909
-
Seat belt connector wire; route
between the console and the buckle, under the buckle spacer
-
Seat belt connector
-
Alarm connector
-
Alarm portion of seat belt alarm
wire harness; route into console along console harness
-
Secure the
seat belt alarm wire harness to the console wire harness using the
remaining cable ties as needed.
Connecting
the Battery
-
Install the
positive battery cable
(red) to the positive
(+) battery post.
-
Install the
negative battery cable
(black) to the
negative (-) battery post.
-
Apply a coat
of Grafo 112X (skin-over) grease, Toro Part No. 505-47 to the battery
posts and battery-cable clamps.
-
Slide the
rubber boot over the positive battery-cable clamp.
-
Close and
latch the battery-compartment cover.
Calibrating
the Kit
-
Move the
machine to level ground and ensure that the vehicle is not moved during
calibration.
-
Locate the
calibration jumper on the alarm harness located near the IMU.
-
Remove the
calibration jumper from the 2 bullet terminals and connect the 2 terminals
together.
-
Turn on the
machine and allow at least 30 seconds for automatic calibration. Once
complete, the InfoCenter will display a calibration
confirmation.
Note: Ensure that the vehicle is not moved during calibration.
-
Turn off
the machine, disconnect the terminals, and install the calibration
jumper onto the 2 bullet terminals.
Testing
the Alarm Function
-
Unlatch the
seat belt.
-
Briefly drive
the machine in an open area.
-
Verify that
the audible alarm is active.
-
Verify that
the visual alarm icon
appears on the
InfoCenter.